CALL US: 0203 8118 306

What Is an Evacuation Lift and When Is One Required?

Evacuating people safely from upper floors has always been one of the toughest aspects of fire and life safety design. For many years, the default assumption in the UK was simple: in a fire, do not use the lifts.

That position is changing. Modern building design increasingly allows for certain lifts to be used as part of a managed evacuation strategy, particularly to support people who cannot easily use stairs. These are known as evacuation lifts.

What is an evacuation lift?

An evacuation lift is a passenger or goods-passenger lift that is specifically designed, built and managed so it can be used as part of an emergency evacuation plan, usually during a fire.

Unlike ordinary passenger lifts, which are typically taken out of service when a fire alarm operates, an evacuation lift is intended to remain available under carefully controlled conditions so that people can be moved away from danger. In most UK guidance this is primarily about helping disabled people and others with reduced mobility to evacuate more quickly and with less risk.

  • They are standard lifts with additional fire and emergency provisions
  • They form part of the wider fire strategy for the building
  • They are usually used for assisted evacuation rather than by all occupants
  • Use in an incident is normally controlled by trained staff or the fire and rescue service

Evacuation lifts should not be confused with lifts used by firefighters. Firefighting lifts have their own set of design requirements and are primarily there to support the fire and rescue service, not day-to-day evacuation of building users.

How does an evacuation lift work in practice?

The technical arrangements vary from building to building but an evacuation lift will typically operate in a more controlled mode during an alarm. This might include some or all of the following features:

  • The lift is recalled automatically to a designated floor when the fire alarm operates
  • Control of the lift is transferred to a secure location such as a fire control point or building control room
  • Only trained staff with keys or access control can move the lift between floors
  • The lift will not stop at a floor that is affected by fire or smoke
  • The doors will only open where it is considered safe to do so
  • Communication systems allow passengers and operators to talk to each other and to the control room
  • There is a protected lobby or refuge at each evacuation floor where people can wait safely until they are taken into the lift

In some designs the lift is intended for fully assisted evacuation only, with trained staff bringing wheelchair users or other mobility-impaired occupants to the lobby and escorting them into and out of the lift. In other cases some independent use may be built in but this still needs to be supported by clear management procedures.

What makes an evacuation lift different from an ordinary lift?

From a user’s point of view an evacuation lift may look very similar to any modern passenger lift. The crucial differences are in the protection, redundancy and controls around the lift and its environment.

Enhanced fire protection

  • A fire-protected lift shaft to minimise smoke and heat entering the lift well
  • Fire-resisting doors and construction around lift lobbies so they act as safe waiting areas
  • Smoke control and ventilation provisions to limit smoke spread to lift lobbies and shafts
  • Protected routes between the lift lobbies and final exits

Power supply and reliability

Guidance associated with standards such as BS 9999 and BS 9991 generally assumes that an evacuation lift will remain available even if the building’s main power supply fails. This may be achieved by:

  • A secondary power supply such as a generator or equivalent life safety arrangement
  • Protected electrical distribution routes from the source to the lift machinery and controls
  • Automatic rescue operation to move the car to a landing and open the doors safely if all power is lost

The detail of what is required in any given building will depend on the applicable standards, the overall fire strategy and the conclusions of the fire risk assessment or fire engineering analysis. Professional advice from competent fire engineers and lift specialists is essential.

Interface with the fire detection and alarm system

Because evacuation lifts are used as part of a managed emergency response, they must be closely integrated with the building’s fire detection and alarm system. Typical features include:

  • Automatic transfer from normal operation to an evacuation mode when the alarm activates
  • Inhibition of stopping at floors where fire detectors or sprinklers have operated
  • Feedback to the fire alarm panel about the status of the lift and any faults

Management and staff training

No evacuation lift can be regarded as safe or effective unless the building’s management team knows how to use it in an emergency. This typically involves:

  • Clear procedures describing who is authorised to control the lift and how they should operate it
  • Personal emergency evacuation plans (PEEPs) for regular building users who may rely on the lift
  • Regular drills or exercises to practise how the lift is used and how refuges are managed
  • Arrangements for maintenance, testing and record keeping

This management layer is just as important as the hardware. Simply installing an evacuation lift is not enough: it has to be supported by a robust fire and evacuation strategy.

When is an evacuation lift required in the UK?

Whether an evacuation lift is required in a particular building is not determined solely by lift standards. It sits at the intersection of building regulations, British Standards and fire safety legislation. It also depends heavily on the use of the building and the needs of its occupants.

The following is a general overview only. It is not legal advice and should always be considered alongside project-specific fire engineering and regulatory input.

Building regulations and fire safety law

In England and Wales the Building Regulations set functional requirements for means of warning and escape, fire spread and access to buildings. Detailed guidance on achieving compliance in many common building types is provided in Approved Document B (fire safety) and Approved Document M (access to and use of buildings) along with relevant British Standards.

Once a building is occupied, the Regulatory Reform (Fire Safety) Order 2005 places duties on a responsible person to take general fire precautions, including arrangements for safe evacuation of all relevant persons from the premises. Comparable legislation applies in Scotland and Northern Ireland.

These documents do not prescribe evacuation lifts for every situation. Instead they point designers and duty-holders towards risk-based solutions that may include evacuation lifts where appropriate.

British Standards and commonly referenced guidance

For many non-residential buildings designers may use BS 9999 (fire safety in the design, management and use of buildings) as an alternative to some of the guidance in Approved Document B. BS 9991 provides similar guidance for residential buildings. Both standards reference the use of evacuation lifts under certain circumstances, particularly as part of strategies for disabled people or where phased evacuation is planned.

More detailed technical provisions for lifts intended to support evacuation of disabled persons are set out in standards within the BS EN 81 series, including a dedicated part for evacuation. These documents concentrate on how a lift should be designed, constructed and equipped if it is to be used as part of an evacuation plan, rather than whether a lift is strictly required.

In practice, decisions on whether an evacuation lift is needed are usually made through a combination of:

  • Compliance with relevant building regulations and associated Approved Documents
  • Application of BS 9999 or BS 9991 where used
  • Fire risk assessments and fire engineering analysis
  • Equality and access considerations, including duties under the Equality Act

Common scenarios where evacuation lifts are often considered

Tall or complex commercial buildings

In tall office buildings, mixed-use developments and other complex commercial schemes stair-only evacuation can become slow and difficult to manage. Where large numbers of people must be moved from upper floors, design teams may use a combination of staircases and evacuation lifts to achieve tenable escape conditions within the required time.

This is particularly relevant where a phased or managed evacuation strategy is adopted rather than simply sounding a general alarm throughout the building. In such cases an evacuation lift can be an important part of the means of escape for staff and visitors who cannot use stairs quickly or safely.

Buildings with significant numbers of disabled or mobility-impaired users

Where a building is intended for regular use by people who cannot easily use stairs it will usually be necessary to consider how they will evacuate independently or with minimal assistance. Examples include workplaces with disabled employees on upper floors, public buildings and civic offices, education buildings and certain healthcare or supported-living environments.

Solutions in these settings might include refuges, evacuation chairs, evacuation lifts or a combination of these measures. The right answer will depend on building layout, staffing levels, the likely number and needs of disabled occupants and discussions with building control and the fire and rescue service.

New build developments with lifts for access

In new developments where lifts are already being provided to meet access requirements, current guidance often favours ensuring at least one lift can in principle support evacuation. In some schemes this is achieved by designing a passenger lift so it can operate as an evacuation lift when needed.

Existing buildings and refurbishment projects

In existing buildings the position can be more complex. There is generally no automatic requirement to upgrade an existing passenger lift to an evacuation lift simply because new standards have been published. However, duties under fire safety law and equality legislation do require duty-holders to keep their arrangements under review.

When major refurbishment or change of use is planned, or when the occupancy profile changes significantly, it is common for fire strategies and evacuation arrangements to be revisited. This is often the point at which property owners consider whether to:

  • Upgrade an existing lift with evacuation features as part of a wider modernisation
  • Install a new evacuation lift in a suitable location
  • Adopt alternative measures if an evacuation lift cannot reasonably be provided

In all cases, competent fire engineering and lift design advice is essential. Local building control bodies and the fire and rescue service may also need to be consulted.

Who decides whether an evacuation lift is necessary?

For a commercial or public building there will usually be several professionals involved in determining whether an evacuation lift is necessary:

  • The client and design team, including architects and building services engineers
  • A fire engineer or fire safety consultant
  • A lift specialist who understands both lift technology and the relevant standards
  • The building control body reviewing compliance with Building Regulations
  • In some cases the local fire and rescue service

For existing occupied buildings, the responsible person under fire safety law and those carrying out the fire risk assessment will have a key role. They need to understand who uses the building, how many people may require assistance and whether current arrangements are adequate.

An experienced lift company, such as Excel Lift Services, can advise on the technical feasibility and implications of providing or upgrading a lift for evacuation use as part of that wider process.

Can an existing lift be converted into an evacuation lift?

In some buildings it may be feasible to adapt an existing lift rather than install a completely new system. Whether this is possible will depend on a combination of structural, electrical, fire safety and control considerations.

Potential upgrades might include:

  • Improving lobby protection and creating suitable refuges
  • Providing protected power supply routes and, where appropriate, a secondary supply
  • Upgrading lift controls so they can interface correctly with the fire alarm system
  • Enhancing communication systems between the lift car, lobbies and control points
  • Updating doors, finishes and signage to match current accessibility expectations

There will be cases where the existing lift location or shaft construction means that achieving full evacuation lift functionality is not realistic. A competent lift specialist will be able to survey the installation, liaise with fire engineers and set out what is possible, what is not and what the cost and programme implications might be.

Key questions for building decision-makers

If you are responsible for a commercial building or estate, the following questions can help you determine whether you should be looking more closely at evacuation lifts:

  • Do we have staff, residents or visitors who cannot evacuate quickly via stairs from upper floors?
  • Are our current evacuation plans for disabled people and others with reduced mobility realistic and regularly tested?
  • Has a competent fire risk assessor or fire engineer reviewed whether an evacuation lift would materially improve safety?
  • If we are planning a refurbishment or new build, have evacuation lift options been considered alongside standard passenger lifts from the outset?
  • Do we understand the ongoing maintenance, testing and management responsibilities that come with an evacuation lift?

If the answer to any of these is uncertain it is worth seeking professional advice. In many cases an early discussion with a lift specialist can reveal options that may not be obvious from a purely architectural or fire engineering viewpoint.

How Excel Lift Services can help

Excel Lift Services works with commercial clients across the UK to design, install, modernise and maintain lifts in offices, public buildings, education, healthcare and other complex environments. The team is experienced in integrating lifts with wider fire and evacuation strategies and in working alongside architects, consultants and fire engineers.

Excel Lift Services can support you with:

  • Feasibility studies on upgrading existing lifts to support evacuation strategies
  • Design and installation of new lifts where evacuation capability is required
  • Modernisation projects that improve reliability, accessibility and energy performance while aligning with current guidance
  • Planned maintenance to keep critical lift systems ready for use when they are needed most

If you are unsure whether your building needs an evacuation lift or want to understand what is realistically achievable within your constraints, Excel Lift Services can provide clear, practical guidance and project support.

To discuss evacuation lifts for your commercial building or to arrange a lift survey, contact Excel Lift Services via the website or speak to the team to arrange a consultation.

Are You In Need Of Elevator Repair?

Speak to us today for more information on the range of lifts we repair and install.