CALL US: 0203 8118 306

What Information Should Be Kept in a Lift Maintenance Log?

A lift maintenance log should record the lift’s identity, service dates, engineer details, reported faults, inspection findings, maintenance tasks, repairs, replacement parts, operational status and outstanding actions. It should also reference relevant service sheets, thorough examination reports and supporting documents so the building’s responsible person can follow each issue from first report to confirmed resolution.

The most useful log is not simply a list of visits. It explains what was found, what was done, whether anything remains unresolved and who needs to act next. For building owners, facilities managers and property managers, that creates a reliable history for day-to-day decisions, contractor handovers and longer-term maintenance planning.

Why does a lift maintenance log matter?

A well-maintained log connects individual events that might otherwise sit in separate emails, contractor portals or paper folders. A door fault reported by reception may lead to an engineer’s visit, a parts quotation and a later repair. Without a joined-up record, the original problem can appear closed simply because someone attended.

Accurate records also help engineers investigate recurring faults. Knowing when a problem happens, what previous testing established and which components have already received attention can make subsequent investigation more focused. The history supports diagnosis but does not replace inspection or testing by a competent lift professional.

For the building team, the log provides visibility of unresolved defects, planned work and restrictions on use. It can support evidence of maintenance management, although keeping records alone does not demonstrate that all applicable safety or legal duties have been met.

Identify the lift clearly before recording any work

Every log needs a stable asset identity. This matters particularly in buildings with several similar lifts where a vague reference such as “main lift” can send a repair history to the wrong asset.

Keep the following information at the front of the record or within the asset profile:

  • Building address and the lift’s location within it.
  • A unique asset number used consistently across reports and quotations.
  • Manufacturer, model and serial number where known.
  • Lift type, such as passenger lift, goods lift or platform lift.
  • Installation date where documented and dates of significant modernisation.
  • Current maintenance provider and relevant contact details.
  • The building contact responsible for coordinating follow-up work.

Where information is unavailable, mark it as unknown rather than guessing. Records for associated equipment should identify which lift they relate to. Keep emergency contact information accessible without allowing it to become outdated when contractors or building personnel change.

Record the essential details of every attendance

Each service visit, breakdown attendance or repair should have its own dated entry. Include the attendance time where relevant, the reason for the visit, the contractor’s name, the engineer’s name or traceable identifier and the service report reference.

Distinguish between a planned maintenance visit and an attendance for a specific fault. A call-out to investigate an intermittent stoppage does not automatically mean the planned maintenance schedule has been completed. Equally, a scheduled service may identify work that needs a separate repair visit.

The entry should describe the scope actually completed. If access restrictions, unavailable parts or another limitation prevented part of the work, record that clearly with the proposed next step. Avoid relying on entries such as “attended” or “service done” when the supporting report contains no useful detail.

Where work takes place over several visits, link the entries using the same job or defect reference.

Separate reported symptoms from confirmed findings

Fault records should distinguish what users observed from what the engineer established. “Lift stopped at the second floor” is a reported symptom. A confirmed technical finding requires appropriate investigation and should be recorded by the competent person carrying it out.

Useful observations include when the fault occurred, which landing was involved, whether it was intermittent and any displayed message reported by users. Record whether people were trapped or whether the lift returned to operation before attendance. Building staff should report what they can observe safely without opening panels or accessing restricted areas.

Possible causes might involve door equipment, controls, electrical supplies or other systems, but the log should not turn an assumption into a diagnosis. If no fault was reproduced during attendance, record that outcome together with the checks completed and any recommended monitoring.

This distinction prevents later engineers from treating an unverified description as an established component failure.

Describe maintenance tasks, repairs and replacement parts

The record should explain the work completed in enough detail to support future maintenance. Link the log to the engineer’s service sheet rather than reducing every visit to a generic tick against “serviced”.

Depending on the work undertaken, relevant details can include:

  • The assemblies or systems inspected and maintained.
  • Adjustments, cleaning or lubrication completed by the engineer.
  • Tests performed and recorded results where applicable.
  • Components repaired or replaced.
  • Part descriptions and identifying references where available.
  • Changes to settings or software where relevant to future servicing.
  • Supporting photographs, test records or technical documents.

If the engineer replaces a component, the record should distinguish that completed repair from a recommendation to replace something later. Where further checks or specialist involvement are necessary, document the limitation. A parts invoice may support the history but does not by itself explain why the repair was needed or whether the fault was resolved.

Make the lift’s operational status unambiguous

Every attendance should leave a clear record of the lift’s status at handover. Was it returned to service, left out of service or subject to a restriction identified by the competent professional? Record who communicated that status and which building representative received the information.

Avoid wording that suggests the lift is ready for use merely because the engineer has left site. Attendance completion and safe return to service are different matters. If the lift remains unavailable, include the reason, the immediate management arrangements and the next agreed action.

Any restrictions or safety instructions should be recorded accurately and communicated through the building’s procedures. A log entry is not a substitute for taking necessary precautions, controlling access or notifying affected people.

Where a later visit changes the status, add a new dated entry. Do not overwrite the earlier record and lose the sequence of decisions.

Track outstanding defects through to closure

An effective lift maintenance log doubles as an action tracker. Each unresolved item needs a description, a responsible party, the required next step and a target date where one has been agreed. Record the engineer’s assessment of urgency without allowing administrative labels to override technical advice.

Useful action stages include reported, investigated, awaiting quotation, awaiting approval, awaiting parts and completed. These stages show why something remains open. They also help distinguish an engineering delay from a decision awaiting the building owner’s authorisation.

Closure should be supported by evidence of the completed work and relevant checks. “Quote accepted” does not mean a repair has happened. “Engineer attended” does not establish that the original defect has been resolved.

Review open items regularly and escalate safety-related concerns promptly through the appropriate process. Do not wait for the next routine record review where the engineer has advised immediate action.

Link maintenance records with thorough examination reports

Keep servicing records distinct from statutory thorough examination documentation while making both easy to retrieve. Maintenance concerns the ongoing upkeep of the lift. A thorough examination has a separate purpose and should not be treated as interchangeable with a service visit.

Where the Lifting Operations and Lifting Equipment Regulations apply, retain the relevant reports and manage any identified defects in accordance with the report and applicable duties. Requirements depend on the equipment and circumstances, so seek competent advice if responsibilities or deadlines are unclear.

The maintenance log can record the examination date, report reference, identified actions and evidence of remedial work. Preserve the original report rather than replacing it with a short summary. A maintenance contractor’s attendance note should not be treated as automatically closing every examination finding.

Keep related documents, such as relevant test reports and commissioning information, organised within the same asset record where available.

Agree who updates the log and checks its accuracy

Engineers should provide the technical account of their work. The building’s designated contact should make sure that reports are received, assigned to the correct asset and followed up. Responsibilities should be clear even where a managing agent oversees the contract on an owner’s behalf.

Building staff can record user reports, periods of unavailability and communications with the contractor. They should not reinterpret technical findings or certify that engineering work is satisfactory without the necessary competence.

After each attendance, check that the report identifies the lift, explains the outcome and highlights outstanding work. Ask the contractor to clarify ambiguous statements rather than filling in gaps from memory.

Handover arrangements matter when staff or service providers change. Transfer the asset history, open actions and supporting documents securely so important knowledge does not leave with an individual’s email account.

Choose a paper or digital system that preserves the history

A paper logbook, a digital asset system or a combination can work if records are accurate, accessible and controlled. The format matters less than whether authorised people can retrieve the complete history when needed.

Digital systems can make searching and linking documents easier. However, access should not depend solely on a contractor portal that may become unavailable when a contract ends. Agree how the building owner can obtain usable copies of service reports and supporting records.

Paper records need a secure location and a reliable method for adding reports. If paper documents are scanned, check that every page is legible and linked to the correct lift.

Whichever system you use, retain earlier versions or an amendment history. Protect personal information and restrict access appropriately. Agree a retention approach that reflects applicable requirements, document types and the value of the asset’s longer-term technical history.

Deal with missing or inconsistent records openly

If the lift’s history is incomplete, start by listing what is available and where the gaps are. Request copies from current or previous contractors, the building owner, managing agents and the relevant examination provider where appropriate.

Do not recreate historic service entries as though they were original records. If information comes from a later conversation or an old invoice, identify the source and its limitations. An invoice may establish that work was billed without showing the precise findings or final operational status.

Where missing records leave uncertainty about unresolved defects or the lift’s condition, arrange a competent review. The appropriate next step may involve checking available documentation, inspecting equipment or undertaking testing where advised.

A current assessment can help establish a reliable starting point. It does not prove that undocumented maintenance happened in the past or remove the need to address any outstanding responsibilities.

Use the history to inform repair and modernisation decisions

Reviewing the log over time can reveal patterns that individual service sheets miss. Repeated symptoms on the same landing, frequent adjustments or recurring component replacements may justify a more detailed investigation.

Compare engineer findings rather than counting call-outs alone. Several reports may relate to one unresolved issue, while apparently similar stoppages may have different causes. Operational context also matters: changes in building use or accidental damage can affect the history.

For repair planning, the records help show what has already been attempted and whether the result lasted. For modernisation planning, they can support discussions about recurring defects, parts availability and the condition of particular systems.

The log should inform an assessment rather than dictate replacement automatically. A competent lift professional needs to consider the equipment’s actual condition and the building’s requirements before recommending repairs, targeted upgrades or wider modernisation.

A practical structure for your next log entry

A consistent entry format makes records easier to compare. Use the following structure alongside the contractor’s detailed service report:

  • Asset and attendance: lift identifier, date, time, contractor, engineer reference and job number.
  • Reason for attendance: planned service, reported fault, repair or follow-up.
  • Reported issue: observed symptoms and relevant circumstances.
  • Technical findings: confirmed findings, investigation limitations and report reference.
  • Work completed: maintenance tasks, repairs, parts and relevant checks.
  • Handover status: operational condition, restrictions and person informed.
  • Follow-up: outstanding actions, responsible person, agreed dates and closure evidence.

Start by reviewing the latest entry for each lift against this structure. Resolve unclear status information first, then organise open defects and missing supporting reports. The aim is a dependable record that helps the next person understand what happened and what still needs attention.

Frequently Asked Questions

How long should lift maintenance records be kept in the UK?

There is no single retention period that should be applied indiscriminately to every lift document. Maintenance records, thorough examination reports and other statutory documents can have different requirements. Set a retention policy with competent advice that reflects the applicable duties and the type of record. Keeping a useful long-term service history can also support fault investigation, asset planning and contractor handovers. Do not assume that an old report can be discarded simply because a newer service visit has taken place. Preserve records relating to unresolved defects and check requirements before deleting or destroying documents.

Do you need specialist software for a lift maintenance log?

Specialist software is not essential for creating a useful maintenance history. A controlled spreadsheet linked to dated service reports may be practical for a small portfolio, while a larger estate may benefit from an asset management system. Choose a format that supports clear asset identification, document retrieval, action ownership and an amendment history. Check backup arrangements and access permissions. If records sit in a maintenance contractor’s portal, establish whether you can export the full history in a usable format before the contract ends. Software should make records easier to manage rather than conceal missing information.

Can residents or tenants see the lift maintenance log?

Access depends on the circumstances, relevant agreements and any applicable information rights. A maintenance log may contain personal details, security-sensitive information or technical material that needs explanation. Building managers can often provide an appropriate summary of lift availability, planned work and progress on reported faults without circulating the complete engineering record. Do not assume either that everyone has an unrestricted right to the full log or that all information must remain confidential. Where a formal request is made, check the relevant obligations and handle personal information appropriately.

What should you record if a scheduled lift service is missed?

Record the planned visit date, when the missed attendance was identified, the contractor’s explanation if provided and the agreed follow-up arrangements. Keep the appointment open rather than marking it complete because a replacement date has been proposed. Ask the maintenance provider whether the delay requires any specific action in light of the lift’s condition, use and existing defects. A missed service does not automatically establish that a lift is unsafe, but uncertainty or known safety concerns need competent assessment. Record the eventual attendance against its actual date without backdating it to the original appointment.

Need clearer lift maintenance records or help with unresolved defects? Excel Lifts brings more than 35 years of lift-industry experience to planned maintenance and repair support. Contact the team to discuss your lift’s history and next steps.

Are You In Need Of Elevator Repair?

Speak to us today for more information on the range of lifts we repair and install.